Microsensors
Our microsensors have been specifically designed for use in museums and preventive conservation.
Product Details
Benefits
This is what makes our innovative product so unique.
Smallest Design
Due to their compact design and optical customization upon customer request, our sensors are nearly invisible.
Highest Precision
Through a special manufacturing process and stringent quality assurance, we ensure the highest level of precision.
Easy to use
Our sensors are plug-and-play and interchangeable with each other.
Applications
Our microsensors are used in display cases, measurements on objects, museum spaces, storage facilities, archives, historic buildings, and more.
Technical Data
Microsensor TRF09tst | |
Dimensions | (6,5 x 22)mm |
Housing | Plug-in |
Measurement Parameters | Temperature and relative humidity |
Relative Humidity | |
Measurement Range | 0%RH to 100%RH |
Accuracy at 25°C | +-2% |
Temperature | |
Accuracy 5°C to 50°C | +-0,5°C |
Microsensor TRF18tst with Highest Accuracy | |
Dimensions | (8 x 35)mm |
Housing | Plug-in |
Measurement Parameters | Temperature and relative humidity |
Relative Humidity | |
Measurement Range | 0%RH to 100%RH |
Accuracy at 25°C | +-1.0%RH |
Temperature | |
Measurement Range | -40°C to 125°C |
Accuracy 5°C to 50°C | +-0.1°C |
Miniature Sensor TRFKDtst | |
Dimensions | (50x26)mm |
Housing | Plug-in |
Measurement Parameters | Temperatur, relative Feuchte und Kohlendioxid |
Relative Feuchte | |
Measurement Range | 0%RH to 100%RH |
Accuracy at 25°C 0-100%RH | +-3% |
Temperature | |
Measurement Range | -40°C to 70°C |
Accuracy 0-50°C | +-(0.4°C + 0.023 x (T[°C]-25°C) |
Carbon Dioxide (CO2) | |
Measurement Range | 400ppm to 10000ppm |
Accuracy 5°C to 50°C | ± (30 ppm + 3%MV) |
VOCtst | |
Dimensions | (8 x 35)mm |
Housing | Plug-in |
Measurement Parameters | VOC |
Total Volatile Organic Compounds (VOC) Measurement Range (Ethanol equivalent) | 0 to 1000ppm |
Reproducibility | < +-5 |
Surface Climate Sensor OTRF | |
Dimensions | (20mm x 10mm x 6mm) |
Housing | Plug-in |
Measurement Parameters | Temperature and relative humidity |
Relative Humidity | |
Measurement Range | 0%RH to 100%RH |
Accuracy at 25°C | +-2% |
Temperature | |
Accuracy 5°C to 50°C | +-0,5°C |
Quotation Request
Microsensors
FAQ - Frequently Asked Questions
Microsensors
Depends on the operating conditions. In the museum climate with values around 50%rH and temperatures around 20°C, an annual check is sufficient. If used outdoors or in high humidity areas, a six-monthly inspection may be necessary. This depends on the requirements for the precision of the measurement.
The sensors are checked in our calibration chamber and if there are deviations > Specification replaced by new sensor elements. Another option is to measure using the CanMeleon 2.0 or CanMeleon Compact. Here it is possible to compensate for smaller deviations.
Yes, the sensors are interchangeable.
Depending on the location and environmental conditions from 10 years to approx. 25 years
Yes, the sensors are available in a wide variety of designs. Depending on the needs of the area of use, the sensors can be made of different colors and materials.